. Accurate control and display of regenerative temp, by using P. I. D. Control.
. Honeycomb rotor is used to ensure constant air dehumidifying effect.
. Microprocessor board is fitted to indicate machine running status and to diagnose malfunctions.
. Motor overload and phase reverse alarm functions are included.
. Return air cooling and filtering are included.
. Under normal state and atmospheric conditions, the humidity content of air can be controlled exactly all year round.
. Inhibits corrosion and polongs service life of the mould, and yet reduces moulding cycle time.
. Air temperature generated by this series of machine is about 30oC, this ensures moisture condensation in the moulding area will not occur on the view window of the moulding machine.
. Supplied as standard, a return air collector is used to collect return air from the moulding area back to this machine and to form a closed-loop air circulation, which is particularly practical in tropical climate.
. Dewpoint monitor can be fitted as option to detect dry air quality.
. Upon request, it can be built to comply with worldwide electrical safety standards(For example: CE, VL, CSA, JIS etc. ).
MODEL |
XMD-500H |
XMD-1000H |
XMD-1500H |
XMD-2000H |
Dry windmill (kw) |
0.75 |
1.5 |
1.5 |
5.5 |
Renewable windmill (kw) |
0.4 |
0.75 |
0.37 |
0.37 |
Dry wind flow (m 3 /hr) |
500 |
1000 |
1500 |
2000 |
Renewable heating (kw) |
5 |
7.2 |
12 |
12 |
Dry wind piping size |
4" |
5" |
8" |
8" |
Renewable wind piping size |
2" |
2.5" |
3" |
3" |
Cooling faucet size |
3/4" PT |
3/4" PT |
3/4" PT |
3/4" PT |
Dry air temperature ( º C) |
30 |
30 |
30 |
30 |
The average dew point temperature (º C ) |
-10 |
-10 |
-10 |
-10 |
Fan pressure (Pa) |
3000 |
3000 |
1400 |
3500 |
Cooling water flow (L/M) |
50 |
50 |
100 |
100 |
Water pressure (kgf/cm 2) |
3~5 |
3~5 |
3~5 |
3~5 |
External size
|
H (mm) |
1685 |
1730 |
1990 |
1990 |
W (mm) |
650 |
800 |
850 |
1150 |
D (mm) |
700 |
805 |
1075 |
1075 |
Weight (kg) |
250 |
300 |
350 |
450 |
Noise dB(A) |
65 |
65 |
65 |